NHG268 Gloss Meter

HG Series Touch Screen Gloss Meter HNG268

HNG series economic gloss meter is independently developed by 3nh, with independent intellectual property. Manufactured according to International standard ISO2813and Chinesestandard GB/T 9754,it is the world's first full large touch screen gloss meter. With GQC6 PC software, gloss measurement is more convenient to use. Stable performance and high accuracy measurement makes it very popular all over the world.


Key Highlights

  • Large Touch Screen Operation, Fully Automatic Calibration

  • Tri-Angle 20°, 60°, 85° Test

  • Display 5 sets of measurement data

  • Basic measurement, statistical measurement, continuous measurement, QC measurement

  • One button for all angles measurement at the same location

  • Input gloss value manually

This NHG268 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)
PRODUCT DETAILS

NHG268 gloss meter features with 20, 60 and 85° angle, manufactured according to ISO2813 and GB/T 9754. It is also compatible with the standards of ASTM D523, ASTM D2457. NHG268 conforms to JJG696 first class gloss meter working requirement, corresponding with CIE 1931(2°) under CIE C light source.

 

NHG268 gloss meter can test material with high gloss (0-2000Gu), and universally apply to paint, ink, stoving varnish, coating, wood products; marble, granite, vitrified polished tile, pottery brick and porcelain; plastic, paper; hardware industries, etc. for gloss measurement and gloss data transmission.


 

Features:

 

1. 20, 60 and 85° in one: from high to low gloss - have the specified angle on hand
2. One button for all angles measurement at the same location
3. Display 5 sets of measurement data, good for comparison
4. Measuring mode: basic measurement, statistical measurement, continuous measurement, QC measurement (only for GQC6 software).  
5. Continuous mode to check uniformity over large areas
6. Connect to PC, more extend functions
7. Input gloss value manually
8. Large touch screen operation, easy to use
9. Beauty appearance, good man-machine communication interface
10. Powerful functions to meet many different requirements
11. Large storage to save over 5000 data
12. Built-in lithium ion rechargeable battery.


 

Specifications:


NHG268 Multi-angle Precise Gloss Meter
Model: NHG268
Measuring Angle 20°/60°/85°                                       
Comply with standard ISO 2813, GB/T 9754, ASTM D 523, ASTM D 2457
Measuring Area (mm) 20°: 10x10    60°: 9x15    85°: 5x36
Measuring Range 20°:0~2000GU   60°:0~1000GU   85°:0~160GU
Division Value 0.1GU
Measurement Range        
Repeatability                        
Reproducibility
0-10GU            10-100GU      100-2000GU
± 0.1GU           ± 0.2GU           ± 0.2%GU
± 0.2GU           ± 0.5GU           ± 0.5%GU
Measurement Standard Conform with JJG696 first class glossmeter working requirement
Chromaticity Corresponding Corresponding with CIE 1931(2°)  under CIE C light source
Errors ±1.2 , ± 1.2%
Measuring Time 1.0s
Dimension L*W*H : 160mm*75mm*90mm
Weight 350g
Language Chinese/English
Battery 3.7V,3200mAh Li-ion Battery ,>10000 times(within 8 hours)
Display TFT 3.5 inch, capacitive touch screen
Interface USB/RS-232
Storage Basic mode: 1000; Statistical Mode: 5000,Continuous mode : 5000
Software GQC6 Quality Control Software with QC report printing functions and more extended functions.
Operation Temperature  0~40℃(32~104°F)
Storage Temperature  -20~50℃(-4~122°F)
Humidity<85% relative humidity,  no condensation
Standard Accessories Power Adapter, USB cable, User Manual, CD (Including QC software), Calibration Plate
Optional Accessories Miniature Printer
Note The specifications are subject to change without notice.


12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

FAQs About Gloss meter

a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

a. Right click "! USB Device" or "! SCI USB2Serial (COM6)", "Update Driver" -> "Install from a list or specific location (Advanced)" -> "Next" ->"Include this location in the search" -> "Browse", specify USB driver file path "CQCS3USB_Driver", click "Next". Then it will install successfully.

b.Detailed installation information please refers to "2.2 Installing USB Driver" in Color Quality Management System User Manual.doc.

a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.

b. Double-click the setup.exe to install CQCS3 software.

c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.

d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.

Related Gloss meter You May Also Like