YH1600 Haze Meter

Benchtop Color Haze Meter YH1600

YH1600 Haze Meter can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full transmittance and fog test.


Key Highlights

  • Double standard ISO & ASTM

  • CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy color space

  • Large-size touch control screen

  • ASTM D1003 uncompensated method, ISO 13468 compensated method, full transmittance, haze test

  • Independent light source detector and temperature sensor

  • Measuring and analyzing fog, color and light transmittance software

  • Color management software

This YH1600 Haze Meter Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

YH1600 Haze Meter can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full transmittance and fog test. Through precise concave grating and 256-pixel CMOS detector, the transmittance curve of transmitted sample can be accurately collected, various chroma data of transmitted sample can be accurately output, and high-precision and repeatable transmittance, fog and chroma data measurement can be realized.

 

Advantages of YH1600 Haze Meter 

1.Double standard ISO & ASTM

Can meet the test standard requirements of different users; meet the standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K 7136

2.Multiple observation light sources

The YH1600 colorimeter provides CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy color space, as well as D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11 and F12 observation light sources, which can meet the special measurement needs under different measurement conditions.

3.Easy operation and faster and more accurate measurement

The YH1600 Haze Meter is equipped with a large-size touch control screen, which is easy and convenient to operate. The 256 pixel dual array CMOS image sensor can realize high accuracy and repeatable transmittance and haze measurement. USB data output unit that interfaces with the laboratory system.

4. Compensation port to make the measurement data more accurate

Meet ASTM D1003 uncompensated method, ISO 13468 compensated method, full transmittance, haze test, provide more accurate test results

5.Dynamic measurement

Independent light source detector and temperature sensor to monitor the light source and environmental changes at all times to ensure reliable test data

6.Convenient measurement and wide sample adaptation

Open measurement area for vertical and horizontal testing to accommodate more samples under test

7.Quality management software

It provides powerful software for measuring and analyzing fog, color and light transmittance, which is suitable for quality monitoring and tabulating management of fog, light transmittance and color data in various industries. Data the management of users on the PC computer, compare the fog, transmittance and color differences, generate test report forms, facilitate customer customization and management.

 

Application of YH1600 Haze Meter 

 

YH1600 Haze Meter is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects.

 

Product model YH1600 Haze Meter 
Illumination mode Transmittance: 0/D (parallel illumination, diffuse receiving) in accordance with standards: ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, JIS K7105, JIS K7361, JIS K 7136
Characteristic The instrument can easily realize ASTM D1003 uncompensated method, ISO 13468 compensation method, full transmittance, fog test. The instrument can accurately collect the transmittance curve of the transmitted sample, and can accurately output various chroma data of the transmitted sample. High hardware configuration, open measurement area, vertical, horizontal testing. It is widely used in glass processing, plastic processing, film, display screen processing, packaging industry, liquid analysis and other aspects.
Integrating sphere size Φ 154 mm
Illumination source 400 ~ 700 nm combined LED light source (wavelength scalable customized)
Light splitting mode Concave grating
Inductor 256 pixel dual array CMOS image sensor
Measuring wavelength range 400 ~ 700 nm (wavelength scalable customization)
Wavelength interval 10 nm
Half bandwidth 10 nm
Determination range of transmittance 0-100%
Measuring aperture Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture)
Sample size Thickness less than 170 mm
Color space CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy
Chromatic formula ΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00
Other chromaticity indicators Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM) WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index
Observer angle 2 °/10 °
Observation light source D65, A, C, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12
Display Spectrogram, sample chroma value, color difference/graph, color graph, color simulation, pass/fail result
Measurement time About 1.5s
Resolution of fog 0.01 unit
Repeatability of nebulization Φ20 mm aperture, less than 0.08 (after instrument preheating and correction, test the standard nebulizer with the nebulization of about 40 at an interval of 5s for 30 times of standard deviation)
Inter-stage difference Φ20 mm aperture, less than 0.4 (after instrument preheating and correction, test the standard deviation between the standard nebulizer of nebulization and the reference value at an interval of 5s)
Dimensions Length X Width X Height = 290X211X511 mm
Weight Approx. 7.6 kg
Power supply mode 24 V DC, supplied by 3A power adapter
Illumination light source lifetime > 3 million measurements in 5 years
Display screen TFT True Color 7 inch, Capacitive Touchscreen
Interface USB, Print Serial , Bluetooth
Stored Data 5,000 samples, 20,000 samples
Language Simplified Chinese, Traditional Chinese, English
Operating Temperature Range 0 to 40 ° C (32 to 104 ° F)
Storage Temperature Range - 20 – 50 ° C (-4 – 122 ° F)
Standard Annex Power adapter, instruction for use, quality management software (download), data cable, 0% calibration box, measuring caliber
Optional Accessories Microprinter, Test Fixture, Standard Fog Disk, Footswitch
Notes: Subject to change without notice

12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

Our Valued Clients

FAQs About Haze Meters

SCI&SCE are two method in the color measurement. SCI means Specular Component Include,SCE means Specular Component Exclude.

Under the method of SCE, only test diffuse refection and exclude specular reflection. In that way, the test result is similar to object color was observed by human eyes.

Under the method SCI, both the diffuse refection and specular reflection will be included. In that way, the value about the color is more objective. It will not effect by the environment condition.

When we choose the instrument, those elements should be taking into consideration.


 The five common gloss levels are:

1. Flat/Matte (0–10 GU)

2. Eggshell (10–25 GU)

3. Satin (26–40 GU)

4. Semi-gloss (41–70 GU)

High Gloss (71–100+ GU)
These levels vary slightly depending on industry and standards used.


a. Right click "! USB Device" or "! SCI USB2Serial (COM6)", "Update Driver" -> "Install from a list or specific location (Advanced)" -> "Next" ->"Include this location in the search" -> "Browse", specify USB driver file path "CQCS3USB_Driver", click "Next". Then it will install successfully.

b.Detailed installation information please refers to "2.2 Installing USB Driver" in Color Quality Management System User Manual.doc.

Readings of gloss meters in gloss units (GU) are used to measure shine on the surface. Low GU (0-10) is matte, 10-70 semi-gloss or satin, and above 70 is glossy. Measurement angle is given to the readings: 60° is the normal, 20° is the high gloss, and 85° is the low gloss.


Threenh Technology with excellent after sale service, Generally, Our Spectrophotometer instrument warranty is one years(Additional support period of 3 years). Within the warranty period, we can offer technique support and parts to parts change, necessarily, our engineers may go to your place for better support. Our instrument have professional After-sales Dept, if you have any technical problem or question with our goods welcome to contact us.

Related Haze Meters You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo