P60(6) Color Light Booth

This P60(6) Color Light Booth Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)
Brand: TILO
Made in China
Configuration: D65, TL84, F, UV,CWF,TL83 six light sources
Weight: 28Kg
Dimensions(WxDxH): 710x530x570 mm


TILO P60(6) color light booth is equipped with 6 light sources. The consistency of the light sources in all Tilo Colour Assessment Cabinets gives excellent viewing conditions for reliable colour critical decisions under consistent lighting.
 
TILO P60(6) color matching light booth can be applied to the industries that need to perform color difference testing as follows: as the premiere designer and manufacturer of color matching instrument products for the Graphic arts, Photographic, Textile, Dyeing, Packaging, Printing, Leather, Inks, Knitwear, Plastic, Automotive and Ceramics industries.



 


Features:


1. TILO Color light booth render color more accurately. With 6 different light sources(D65, TL84, CWF, TL83, F, UV), which can detect the metamerism. 
2. Meets or exceeds major international standards for visual color evaluation including: ASTM D1729, ISO3664, DIN, ANSI and BSI. 
3. Easy to operate by using individual switches for each light source.
4. Elapsed time meter for tracking optimal lamp replacement. 
5. Automatically alternating among light sources.
6. No warm-up time or flickering which insures quick and reliable color judgment.
7. Economic power consumption and low heat generation for high light efficiency.
8. The dimension can be made by customized. 
 

 



 

Specifications:


Order No. Name Model D65 TL84 F UV CWF TL83 Voltage
10113  Standard light source booth P60(6) six light source(220V) 2pcs 2pcs 4pcs 1pcs 2pcs 2pcs 220V/50Hz
10813 Standard light source booth P60(6) six light source(115V) 2pcs 2pcs 4pcs 1pcs 2pcs 2pcs 115V/60Hz 

Optional accessories: light source diffuser 45 degree standard stand.

 

Light Sources:

 

Light Source Color viewing booths application Color temperature(k) Power(W)
D65 International standard Artificial Daylight 6500 18
TL84 Applied to stores in Europe, Japan and China 4000 18
CWF (Cool White Fluorescent) American Standard 4150 18
F/A "Sun-setting Light Yellow" incandescent light source(imitation of sunset) 2700 40
UV Viewing under ultraviolet light to detect and evaluate optical brighteners
or fluorescent pigments
Wave length:365nm 20
TL83 Warm White Fluorescent American Standard 3000 18

Our Valued Clients

FAQs About  Light Booth

The ΔE (Delta E) formula of the CIELAB color space is usually used to measure color difference. The difference is measured in a colorimeter or spectrophotometer to gauge the level of perceptibility of the difference between two samples in terms of L*a*b*.


The gloss meter is used to measure gloss at typical angles (typically 20°, 60°, or 85°). The instrument illuminates the material and measures the amount of light reflected and states the outcome in gloss units (GU), which is related to perceived brilliance.


The measurement of color varies according to context in several units. Such common units are L*a*b* (CIELAB), RGB (Red-Green-Blue), and color difference (Delta E). In light absorption, there are no units assigned to absorbance. But the quantitative analysis of absorbance obeys Beer's Law in colorimetry.

The repeatability is an important parameter for the accuracy of the colorimeter. Threenh Technology portable colorimeter for color measurements tandard deviation ΔE*ab is within 0.03 (Measurement condition: the average value of 30 measurements on the white board at an interval of 3s after calibration). Each colorimeter can pass the qualified inspection before leaving the factory to ensure it conforms to the standard of China Metrology Institute.

The concentration of colored compounds in a solution is determined by the use of a colorimeter test. It can be used to measure the quality of the product. The colorimeter test determines the presence of contamination or observes chemical reactions by measuring the extent to which a solution absorbs light at a given wavelength.


a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.

b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.

c. Change the USB cable or change the USB port in you PC.

Related Light Booth You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy