Benchtop Color Haze Meter YS6002

This Benchtop Color Haze Meter YS6002 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

Brief Introduction:

YS6002 benchtop color haze meter is developed by 3nh independently with proprietary intellectua property. This machine adopts transmittance optical geometry d/0 (diffused illumination, 0-degree viewing
angle) which confirms to CIE 15 standard. It can also realized the the optical geometry 0/0 (parallel illumination, 0-degree viewing angle).

YS6002 color haze meter uses 360~780nm composite full spectrum LED light source (which is closed to the spectrum of D65), and it can realize intervals 10nm spectrum by precision concave grating and 256 Image Element CMOS Sensor. Accordance with industry-standard, YS6002 will give the accuracy result for the measurement of haze, transmittance, chromaticity, color difference, WI, YI, Pt-Co Index and Gardner index etc. It is wildly used in the field of glass processing, plastic processing, film manufacturing, display screen processing and packaging industry, liquid pharmaceutical analysis, laboratory etc.

Features:

a. High configuration for the handware: 7 inch capacitive touch screen; 25000 data storage ; with USD / Bluetooth data port.

b. With high optical configuration and resolution, 154mm integrating sphere, concave grating, 256 Image Element CMOS Sensor, dual light path;

c. Adopt 360~780nm composite full spectrum LED light source (which is closed to the spectrum of D65), which is low power consumption and long life time.

d. Easy realize the precision measurement for 3 kinds of light sources A,C and D65 for haze (ASTM D1003/1044), transmittance, Pt-Co Index and Gardner index.

e. Multiple measurement modes : quality control mode and sample mode to meet more customers’ requirement;

f. Independent light source detector and built-in temperature sensor will continuously monitor the change of light sources and environment to ensure the measurement more reliable.

g. Observer angle 2/10, multiple light sources, multiple color spaces, multiple chromaticity to meet different kinds of customers’ testing requirements.

h. Good man-machine interactive to ensure the measurement accuracy and stable;

i. More powerful extended functions at the PC software.


Model YS6002

Optical Geometry
Transmittance:d/0 (diffused illumination, 0-degree viewing angle);
similar to CIE15 standard 0/0(parallel illumination, 0-degree viewing angle);
Confirms to the standard of ASTM D1003/1044, CIE No.15, GB/T 3978, GB
2893, GB/T 18833, ASTM E308, DIN5033 Teil7

Application
wildly used in the field of glass processing, plastic processing, film
manufacturing, display screen processing and packaging industry, liquid
pharmaceutical analysis, laboratory etc.
Intergrating Sphere Size Φ154mm
Light Source 360~780nm Combined LED Lamp
Spectral Separation
Device
Concave-Grating
Detector 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360~780nm
Wavelength Pitch 10nm
Half Bandwidth 10nm
Reflectance Range 0~200%
Measurement Aperture Transmittance: Φ25.4mm
Color Spaces CIE LAB,XYZ,Yxy,LCh,CIE LUV, Musell,s-RGB, HunterLab,βxy,DIN Lab99
Color Difference
Formulas
ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1), ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)

Other Colorimetric Data
Haze (ASTM D1003/1044),transmittance rate T,
WI(ASTM E313,CIE/ISO,AATCC,Hunter),
YI(ASTM D1925,ASTM 313),
TI(ASTM E313,CIE/ISO),
Mt(Matamerism Index ),
Color Strength, Staining fastness,Color Strength, Opacity,
Pt-Co index and Gardner index
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75, F1,F2,F3,F4,F5,F6,F7, F8,F9,F10,F11,F12
Display Data Spectral/Values, Chromaticity Values, Color Difference Values/Graph,Color
Diagram, Color Simulation, Pass/ Fall Result, Color Offset
Measurement Time About 1.5s

Repeatability
Spectral transmittance: for test transmission reference white within ΔE*ab
0.05% (400~700nm: within 0.04%);
Chromaticity Data: Φ25.4mm,within ΔE*ab 0.03 (after do warm-up and
calibration, it is the average value to measure transmission reference white
plate for 30 times at 5 second intervals)
Inter-instrument
Agreement
Φ25.4mm,within ΔE*ab 0.15 (average value for 5 pcs standard transmittance
color plates measurement )
Size 370X300X200mm(L*W*H)
Weight About 9.6kg
Power DC 24V,3A Power Adapter
Illuminant Life Span 5 years, more than 3,000,000 times measurement
Screen 7-inch TFT Capacity Touch Screen Display
Interface USB,Printing Port
Storage Standard:5000; Sample:20000
Language Simplified Chinese, Traditional Chinese, English
Working Temperature 0~40℃(32~104°F)
Storage Temperature -20~50℃(-4~122°F)

Standard Accessory
Power Adapter, User Manual, QC software(please download from website),
USB cable, reflectance white and black board, transmittance black board,
25.4mm aperture, transmissive test component
Optional Accessory Miniature- printer
Note The specifications are subject to change without notice.

12 Quality Inspection Processes

With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.

DFM Analysis
DFM Analysis
Dimensional Tolerance
Dimensional Tolerance
Material Testing
Material Testing
CNC Machining
CNC Machining
FQC Detection
FQC Detection
SPC / CPK
SPC / CPK
Problem Found
Problem Found
Problem Solving
Problem Solving
OQC Detection
OQC Detection
Surface Treatment
Surface Treatment
Full Inspection
Full Inspection
Package
Package

FAQs About Haze Meters

a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.

b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.

There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)

a. Turning on

b. Removing measuring aperture, install the needed measuring aperture.

c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.

d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.

e. Replace completed.

a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.

b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.

c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.

d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.

e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.

a. Right click "! USB Device" or "! SCI USB2Serial (COM6)", "Update Driver" -> "Install from a list or specific location (Advanced)" -> "Next" ->"Include this location in the search" -> "Browse", specify USB driver file path "CQCS3USB_Driver", click "Next". Then it will install successfully.

b.Detailed installation information please refers to "2.2 Installing USB Driver" in Color Quality Management System User Manual.doc.

D/8°and 45°/0°are two kinds of illumination geometry with different optical geometry design. D/8°illumination geometry is more widely used for the color comparison and measurement of high-gloss materials; 45°/0°illumination geometry is mainly used in printing and packaging industries. 