The dual-angle gloss meter YG47

Basic Handheld Digital Gloss Meter YG47

YG47 is a full-featured Handheld Digital gloss meter used by professionals with wide ranging surface quality inspection projects and sufurce gloss measurement challenges. It uses a two measuring angles of 45° and 75° to accurately measure the gloss of a product surface and is widely used in gloss measurement and quality inspection in industries such as ceramics, films, paper, and plastics.


Key Highlights

  • Measuring range: 45°: 0~800GU, 75°: 0~150GU;

  • Repeatability: 0~100GU: ±0.2GU; 100~800GU:±0.2%GU;

  • Auto calibration / manual calibration

  • Large Storing data: 30000

  • One charged battery can measure more than 10,000 times

  • Powerful PC data management software, online measurement, printing test reports, data transmission and more

This YG47 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)

The dual-angle gloss meter YG47 is a high-precision portable gloss meter developed by 3nh. The instrument has two measuring angles of 45° and 75°, and the gloss at different angles can be measured simultaneously. The YG47 gloss meter is designed for the ceramic, film, paper, plastic and other industries for measuring the gloss of mirror surfaces.

 

 

Product Features of Dual Angle High Precision Gloss Meter YG47

 

1. Dual-angle design

The instrument has two measuring angles of 45° and 75°. It can measure at a single angle or at two angles at the same time, which makes it more versatile.

Dual-angle design

2. High measurement accuracy

The carefully adjusted measurement system and optical path layout ensure stable and accurate gloss measurement , meeting the requirements of JJG 696 working gloss meter, with superior performance, which can fully match the test data of imported gloss meters.

High measurement accuracy

3. Multi-mode measurement

Supports switching between basic mode, statistical mode, continuous mode, and quality control mode to adapt to different application scenarios. The normal mode allows for immediate measurement and fast readings; the quality control mode allows for custom upper and lower limits to achieve fast incoming material testing .

Multi-mode measurement

4. Calibration function

Supports calibration and has the function of automatically checking the calibration standard plate to ensure the accuracy and reliability of long-term measurement.

 Calibration function

5. Low power consumption

A fully charged AA alkaline battery or NiMH rechargeable battery can measure more than 10,000 times.

Low power consumption

6. Simple operation, easy to use

The instrument is easy to operate and can be used immediately after being turned on. Data can be locked with one button. No complicated settings are required and the measurement can be completed in 0.5 seconds.

Simple operation, easy to use

7. Lightweight and portable

The instrument is designed based on ergonomics, with a compact and beautiful appearance and a comfortable grip. It is not only suitable for precise measurement in the laboratory, but also convenient for flexible application in the production site.

 Lightweight and portable

8. PC quality management software

The instrument is equipped with powerful PC data management software, which supports online measurement, printing test reports, data transmission and more functional expansion.

PC quality management software

 

Dual-angle high-precision gloss meter YG47 technical parameters

 

Product number YG47 Dual Angle High Precision Gloss Meter
Measuring Angles 45°& 75°
Measuring spot(mm) 45°: 10x13, 75°:4x6
Measuring range 45°: 0~800GU
75°: 0~150GU
Graduation value 0~100GU:0.1GU;
100~800GU:1GU;
characteristic It can be used for gloss measurement and gloss data transmission in paint, ink, coating, paper printing, plastic electronics, furniture, ceramics, electroplating, hardware, marble and other industries.
Measurement Mode Basic mode, statistical mode, continuous mode, quality control mode
measure time 0.5 seconds/per angle
Repeatability 0~100GU: ±0.2GU ;
100~800GU:±0.2%GU
accuracy Meet the requirements of JJG 696 working gloss meter
Automatic shutdown time 30~120 seconds optional
Long time calibration Auto Identify Calibration Board and Calibrate / manual calibration
language Simplified Chinese, English, Traditional Chinese
Storing data 35,000 (15,000 in basic mode and continuous mode, 10,000 in quality control mode, 10,000 in statistical mode)
Display 2.3 inch black and white display
size 160X52X84mm
weight About 300g (including calibration box and batteries)
power supply 1 AA alkaline battery or NiMH rechargeable battery, can measure more than 10,000 times; or use USB port
interface USB
PC Software GQC6 quality management software, quality inspection report printing, more functional expansion
Operating temperature range 0~40°C (32~104°F)
Storage temperature range -20~50°C (-4~122°F)
humidity Less than 85% RH, no condensation
Standard accessories USB data cable, instruction manual, GQC quality management software (download from official website or provided by after-sales), calibration board
Optional accessories Micro printer, Bluetooth 5.0 adapter
Note The technical parameters are for reference only, please refer to the actual products sold



Our Valued Clients

FAQs About YG47 Gloss meter

Powder paint gloss levels are commonly classified as:

● Flat/Matte: 0–10 GU

● Satin: 10–40 GU

● Semi-Gloss: 40–70 GU

● Gloss: 70–85 GU

High Gloss: 85+ GU
These ranges can vary by manufacturer and application angle.


Powder paint gloss levels are classified as:

● Flat: 0–10 GU

● Satin: 11–40 GU

● Semi-gloss: 41–70 GU

● Gloss: 71–85 GU

● High Gloss: 86+ GU
 

These are measured at a 60° angle for standardization.


The most common standard measuring gloss is ASTM D523, which covers the procedures of using a gloss meter at 20°, 60°, and 85° angles. The other international standard that is widely used in industrial and laboratory applications is the ISO 2813.


 A gloss meter measures the amount of light reflected from a surface at a specific angle. It's commonly used to assess surface finishes such as paint, coatings, plastics, and paper for consistency, quality control, and visual appearance evaluation.


Readings of gloss meters in gloss units (GU) are used to measure shine on the surface. Low GU (0-10) is matte, 10-70 semi-gloss or satin, and above 70 is glossy. Measurement angle is given to the readings: 60° is the normal, 20° is the high gloss, and 85° is the low gloss.


Related Gloss meter You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy