High-precision Portable Color Difference Meter
The PS2010 is a compact, handheld intelligent digital display spectrocolorimeter; PS2010 is designed for precision and portability, can accurately measure samples of various shapes and sizes, suitable for plastic electronics, paint ink, textile and garment printing, printing, ceramics industries, delivering high-accuracy color measurement results.
Key Highlights
D/8 optical structure and SCI/SCE mode
400~700nm full waveband balanced LED light source
CMOS dual beam splitting sensor
Automatic whiteboard calibration
Multiple color measurement spaces
Reliable repeatability (ΔEab ≤0.04) and inter-instrument agreement (ΔEab ≤0.4)
2.8 inch TFT Capacitive Touch Screen
"Fat girl" is the nickname of PS20 series domestic color spectrometer. It is serious about color measurement and high user satisfaction.
PS2010 "Fat girl" spectrocolorimeter is 3nh developed by CMOS dual-channel spectrocolorimeter sensor, which is not only a colorimeter, but also a spectrocolorimeter, with excellent repeatability and the inner-instrument error. The measurement data is stable, accurate and reliable. with a comfortable and round appearance more people love it. It also has quality management software facilitate quality monitoring and data management.
PS2010 spectrocolorimeter is equipped with single aperture:Φ8mm flat, widely used for plastic electronics, paint ink, textile and garment printing, printing, ceramics and other industries color difference quality control.
PS2010 spectrocolorimeter adopts D/8(diffused illumination, 8-degree viewing angle) which is widely applicable in the world, and SCI/SCE (specular component included/specular component excluded) Synthesis technology. It is suitable for color management and quality control in various industries such as color matching and coating, textile, plastic, food, building materials, cosmetics, etc.
The 400~700nm full waveband balanced LED light source ensures sufficient spectral distribution in the visible light range, avoids the spectral loss of white LED in specific waveband, Fluorescent materials can also be easily measured and ensures the measurement speed and accuracy of the measurement results.
High speed and high sensitivity CMOS dual beam splitter sensor makes color data processing more efficient and accurate.
The spectrocolorimeter PS2010 is equipped with an intelligent calibration base. Contact automatic whiteboard calibration is available, professional standard whiteboard reflectivity R%≥95%, good surface uniformity. It has high stability and can obtain repeated and accurate data.
The spectrocolorimeter PS2010 support CIE LAB,XYZ,Yxy, LCh, CIE LUV,S- RGB, βxy, DIN Lab99 Color space and D65, A, C, D50, D55, D75, F1, F2(CWF) ,F3, F4 F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30), U35, NBF, ID50, ID65 multiple illumination source, Meet different measurement requirements.
The fitted palm is suitable for continuous detection, which makes you fast and easy to use. An easy to measure device for automatic measurement is added. Which is portable, fast, easy to measure and use.
Each PS2010 spectrocolorimeter has been verified and tested. After leaving the factory, each instrument is verified according to the measurement standards of authoritative verification departments, and the measurement data are traceable to the National Metro technical Institute to ensure the authority of the instrument test data.
SQCX quality management software with PS2010 spectrocolorimeter is suitable for quality monitoring and color data management in various industries. Data the user's color management, compare color differences, generate test reports, provide multiple color space measurement data, and customize the customer's color management.
Technical Specification
Model | PS2010 spectrocolorimeter |
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle), SCI/SCE (specular component included/specular component excluded) Mode, Comply to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Characteristic | Adopt CMOS dual beam splitting sensor; Used for color difference quality control in plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics and other industries. |
Light Source | Combined full spectrum LED light source |
Integrating Sphere Size | Φ40mm |
Sensor | CMOS dual beam splitting sensor |
Wavelength Range | 400-700nm |
Measuring Aperture | Single aperture:Φ8mm/Φ10mm (flat) |
Specular Component | SCI/SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94 ,ΔE*cmc(2:1),ΔE*cmc(1:1) ,ΔE*00, DINΔE99, ΔE(Hunter) |
Other Colorimetric Index | Spectral reflectance, WI(ASTM E313,CIE/ISO,AATCC,Hunter), YI(ASTM D1925,ASTM 313),Metamerism Index Mt,Staining Fastness, Color Fastness,Color Strength, Opacity,555 tone classification, Munsell(C/2)(Partially realize through the PC software /APP software) |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75, F1,F2(CWF),F3,F4,F5,F6, F7(DLF),F8,F9,F10(TPL5), F11(TL84),F12(TL83/U30),U35,NBF,ID50,ID65(Partially realize through the PC software /APP software) |
Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
Measuring Time | Abou1s |
Repeatability | Chromaticity value: MAV/SCI, within ΔE*ab 0.04 (After preheating and correction,the average value of the whiteboard was measured for 30 times at an interval of 5s);Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400nm to 700nm: within 0.2%) |
Inter-instrument Error |
MAV/SCI, Within ΔE*ab 0.4 (Average for 12 BCRA Series II color tiles) |
Displayed Accuracy | 0.01 |
Measured Reflectance Range | 0-200% |
Reflectance Resolution | 0.01% |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Locating Method | Stabilizer position |
White Calibration mode | Contact type automatic calibration |
Dimension | 94X68X188mm |
Weight | About 410g |
Battery | Lithium battery,3.7V,5000mAh,8000 cycles in 8 hours |
Illuminant Life Span | More than 1.2 million measurements over 10 years |
Screen | 2.8 inch TFT true color, Capacitive Touch Screen |
Interface | USB |
Data Storage | Standard 500Pcs, Sample 5000Pcs(One data is able to include SCI/SCE); PC mass storage |
Software support | Windows |
Language | Simplified Chinese, English, Traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing),Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, USB Cable, User Guide, SQCX PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, Aperture |
Optional Accessory | USB Micro Printer, Powder Test Box |
Notes | Technical parameters are only for reference, subject to the actual sale of the product |
With 12 rigorous quality inspection processes in place, we ensure a high yield rate of up to 98% for batch processed precision parts.
FAQs About Spectrocolorimeter
Now our testing machines have been sold to more than 80 countries, like USA, Canada, Russia,UK, Italy, Germany, European , India, Pakistan, Philippine, Singapore, Malaysia,Thailand , Vietnam, Korea,Saudi Arabia,Brazil...and so on. We sell to the global market.
With centers in 20 countries, including India, Japan, USA, Germany, Singapore, China, South Korea, and Taiwan, Threenh Technology’ s service network aims to provide customers with convenient access to service globally. With over 1 million measuring instruments sold, our expertise is our greatest asset, enabling us to work with our customers on solutions to complex measurement challenges.
a. It’s needed to perform manual calibration for NH310 when first starting.
b. In the subsequent starting, NH310 will perform auto calibration at startup. No need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH310 measured data is not accurate.
The Ideal Accurate and User - Friendly Spectrophotometer for Your Needs
This Spectrophotometer device measures the reflectivity,absorbance, transmittance, and fluorescence of light passing through samples, providing invaluable data for a wide range of applications, provide unrivaled accuracy for reliable results.
Selecting an appropriate spectrophotometer offers significant advantages for precision color analysis and quality control. When choosing an accurate and user - friendly spectrophotometer, consider factors such as wavelength range, sensitivity, sample handling options, and available software features. By investing in the right spectrophotometer, you can streamline your analytical processes, obtain more accurate results, and enhance the overall efficiency of your laboratory or industrial operations.
Choosing the right model—whether portable, benchtop, or inline—aligns technology with specific industry needs, ensuring long-term reliability and optimized color management.
a. Users must specify Standard File Name, Sample File Name and Sample Database File Name when first use.
b.Standard File is use to store standard measurement data. Sample File is used to store sample measurement data. Sample Database File is used to store the measured data exported from sample records.
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.