The outstanding precision and reliability of the haze meter, as well as its ease of use, have made the haze meter the standard for transparency measurement in the glass, plastic, film and packaging industries.
Optimize Surface Quality with Advanced Haze Meters
3nh Color Haze Meter can easily realize ASTM D1003 non-compensation method, ISO 13468 compensation method, full light transmittance, haze test, clarity test.With the precision concave grating and 256 pixel CMOS detector, it can accurately collect the transmittance curve of the transmitted sample, accurately output the various chromaticity data of the transmitted sample, and realize the high precision and repeatable measurement of the transmittance, haze and chromaticity data.
3nh YH1810 Color Haze Meter can easily realize ASTM D1003 non- compensation method,ISO 13468compensation method, full light transmittance, haze test,clarity test.With the precision concave grating and 256 pixel CMOS detector, it can accurately collect the transmittance curve of the transmitted sample, accurately output the various chromaticity data of the transmitted sample, and realize the high precision and repeatable measurement of the transmittance, haze and chromaticity data.
The instrument can easily implement ASTM D1003 non-compensation method, ISO 13468compensation method, total transmittance, haze test, and clarity test.
The hardware configuration is high, the measurement area is open, and the vertical and horizontal tests can be performed.
A variety of measuring fixtures help you easily measure various samples
Our team will assist you in choosing the Haze Meter Instrument best suited to your environment and technical requirements. Don't hesitate to contact us for a quote, a demonstration, or personalized advice.
FAQs About Haze Meters
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
a. It’s needed to perform manual calibration for NH300 when first starting.
b. In the subsequent starting, no need to perform manual calibration.
c. Suggestion: it’s best to perform manual calibration once a week or when NH300 measured data is not accurate.
High Measurement Accuracy and Stability: Low ΔE fluctuation (e.g., NH300: ΔE < 0.07; NR10QC: ΔE ≤ 0.03 short-term repeatability); Reliable sensors (CMOS dual-beam/silicon photodiode) and long-lasting light sources (1.6M–3M measurements over 5 years).
User-friendly Design and Convenient Operation: Intuitive interfaces (e.g., NH300’s “fool-proof” operation), auto-calibration, and ergonomic grips for extended use; Versatile positioning (light/cross alignment) for precise measurements.
Robust Design: Our colorimter instruments are designed to withstand rigorous use, providing long-term reliability. Rechargeable lithium batteries enable 5,000–6,000 measurements per charge (e.g., NH300/TS7030), ensuring cost-effective durability.
PC Software Support for Functionality Expansion: PC software (e.g., CQCS3) supports color difference analysis, chromaticity indexing, and sample library management.
Global customer support: Our global presence across regions ensures you get the service and maintenance support you need to keep your instrument at peak performance.
Multiple Measurement Apertures and Application Scenarios: Multiple measurement apertures, different models have different measurement apertures and some models offer multiple optional apertures. Applicable to plastic electronics, paint and ink, textile and garment printing and dyeing, printing, ceramics, automotive, food, medicine and other industries for color quality control and color difference detection.
a. If this phenomenon occurred, it means the battery power is not enough. You need to charge the battery.
b. When charge the battery, please insert the battery to the instrument, and plug in the adapter to charge the battery. After 5 minutes, the instrument can be turned on.
c. If the instrument still cannot be turned on after charging 5 minutes, you can pull out the adapter and re-plug in to check it. Or repeat this operation.
d. If the instrument still cannot be turned on after charging 5 minutes, you can turn off the colorimeter and turn on it again to check it. Or repeat this operation.
e. If you have tried all the methods above but the colorimeter still cannot be turned on, please change the battery.
SCI&SCE are two method in the color measurement. SCI means Specular Component Include,SCE means Specular Component Exclude.
Under the method of SCE, only test diffuse refection and exclude specular reflection. In that way, the test result is similar to object color was observed by human eyes.
Under the method SCI, both the diffuse refection and specular reflection will be included. In that way, the value about the color is more objective. It will not effect by the environment condition.
When we choose the instrument, those elements should be taking into consideration.