The 3nh Color Test Chart is a professional color calibration and inspection tool developed by ThreeNH, designed to accurately verify the accuracy and stability of color measurement instruments or assist in data calibration for color management processes.
High-Precision Color Reproduction: Crafted with international standard color card technology, covering multiple standard color gamuts (such as Munsell and Pantone equivalent colors). Color patch values are precisely spectrally calibrated with errors below industry standards (e.g., ΔE≤1.0).
Durable Material: Features a waterproof and scratch-resistant coating, suitable for long-term frequent use in laboratories, production lines, and other scenarios.
As a global leader in image quality testing, we leverage our expertise in image quality testing, equipment, and knowledge to help companies across industries worldwide improve their imaging devices.
Standard camera testing typically covers multiple image quality metrics such as resolution, texture detail retention, noise, dynamic range, color accuracy, distortion, shading non-uniformity, and chromatic aberration. Camera systems often require comprehensive multi-dimensional evaluation.
Through the efforts of our R&D department and the introduction of high-precision production equipment, Threenh has gained the capability to customize various types of test charts. We can produce all kinds of transmission-type test charts (e.g., film charts) and reflection-type test charts according to clients’ specified drawings. Commonly used camera testing charts such as resolution charts, color bar charts, distortion test charts, grayscale charts, and dynamic range test charts can all be customized, significantly reducing costs for high-tech enterprises globally.
Sine Image's business scope includes:
R&D, production, and sales of camera/lens test charts and testing equipment;
Development of camera/lens testing software and image quality analysis software;
Provision of solutions for camera module focusing platforms, automatic inspection platforms, and complete machine testing;
Technical R&D in intelligent recognition, machine vision, and gratings.
Sine Image owns two core businesses:
S-imageTest: Image quality analysis software
ColorFilm: Dedicated to providing supporting product processing and solutions for global large/medium enterprises and institutions.
All test charts are fully customizable. We maintain complete product and customer archives, ensuring each chart undergoes rigorous testing exceeding industry standards before shipment, with guaranteed consistency across batches. As a professional Chinese company specializing in independent R&D and production of high-definition black/white and color test charts, Sine Image has introduced a full series of imported production and inspection equipment for image test charts.
Rapid Delivery: Customized test charts available within 1–3 days
Precision Craftsmanship: High-definition laser scanning technology
Premium Materials:
Transmission materials: Imported film
Glass: Optical-grade impurity-free diffuser glass
Reflection materials: Imported photo paper, water-resistant, wear-resistant, and fade-proof for 20+ years
Stringent Quality Control:
Line uniformity tested with precision optical instruments
OD (optical density) and color parameters measured via cut-edeg densitometers and color difference meters
FAQs About Test Charts
a. Check whether the USB cable is connected. If not, please connect it. Check whether the connection is effective. You can re-plug the USB cable to test.
b. If the USB cable is connected well but the interface still displays "USB Disconnect", please re-start the colorimeter and enter "Menu" -"Comm"to start the communication.
c. Change the USB cable or change the USB port in you PC.
a. Before installation, please Copy CQCS3 folder to your computer and don’t remove any files in CQCS3 folder.
b. Double-click the setup.exe to install CQCS3 software.
c. Then double-click Install.bat under the CQCS3USB_Driver file to install the driver.
d. Detailed installation information please read the "Installing Software" under CQCS3 User manual.doc.
a. Connect colorimeter to the PC with USB cable.
b. Turn on the colorimeter to enter main menu. Select "Comm" and press "Enter" key to start communication.
c. Right click on "My Computer" on the desktop. Click "Manage" -> "Device Manager" -> "Ports", you can see similar display as "SCI USB2Serial (COM6)".
d. Click "Settings->Communication Parameters" in CQCS3 software interface. Select the corresponding port in "Serial Port".
There are three measuring apertures for NH310: Φ8mm (standard accessory), Φ4mm (standard accessory), extended Φ8mm (optional accessory)
a. Turning on
b. Removing measuring aperture, install the needed measuring aperture.
c. Select "Settings-Aperture Setting" in main menu to select corresponding measuring aperture.
d. After selecting aperture, the instrument will display "White and Black Calibration" interface. White and black calibration must be performed.
e. Replace completed.