Tabletop Spectrophotometer YS6010

Helps Enterprises Improve Product Quality

With its excellent measurement accuracy and stability, YS6010 assists enterprises in strictly controlling the color quality of products, enhancing product competitiveness, and winning market favor.7-inch TFT true color capacitive touchscreen, full light source, illumination mode: reflection D/8° and transmission D/0° (including/excluding UV measurement). It features stable color measurement and large storage capacity.


Key Highlights

  • 256 Double Array CMOS Image Sensor

  • φ25.4mm/15mm/8mm/4mm 4 measuring apertures

  • 7 inches TFT Color Capacitive Touch-screen

  • Built-in camera locating

  • PreciseLab data, used for color matching and accurate color transmission

  • Data storage 20000 pieces test result

  • Powerful extended functions at the PC software

This YS6010 Instrument are Certified with
certify
1 Years Warranty (Additional support period of 3 years)


One Key to Complete Intelligent Color Measurement

YS6010 is a benchtop grating spectrophotometer instrument which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments.

YS6010 Benchtop Grating Spectrophotometer

Features

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9. A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application Industry

YS6010 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
 Color measurement of liquids in chemical enterprises

YS6010 helps enterprises improve product quality! 

With its excellent measurement accuracy and stability, YS6010 assists enterprises in strictly controlling product color quality, enhancing product competitiveness, and winning market favor.


YS6010 Technical Specification
 

ModelYS6010 Benchtop Spectrophotometer
Optical GeometryReflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         
SCI (specular component included)/SCE (specular component excluded) ;                                          Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     
SCI (specular component included)/SCE (specular component excluded) ;                                          Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
ApplicationIt is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere SizeΦ154mm
Light Source360 nm to 780 nm, Combined LED Light, 400nm cut-off light source
Spectrophotometric ModeConcave Grating
Sensor256 Image Element Double Array CMOS Image Sensor
Wavelength Range360-780nm
Wavelength Interval10nm
Semiband Width5nm
Measured Reflectance Range0-200%
Measuring ApertureReflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;                         
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position
Specular ComponentReflectance: SCI&SCE  / Transmittance: SCI&SCE
Color SpaceCIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference FormulaΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric IndexWI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
APHA/Hazen/Pt-Co, Saybolt
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, 555 Index, Haze(ASTM D1003)
Observer Angle2°/10°
IlluminantD65,A,C,D50,D55,D75, F1,F2,F3,F4,F5,F6, F7,F8,F9,F10,F11,F12, CWF,DLF,TL83,TL84,TPL5,U30
Displayed DataSpectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring TimeAbout 2.4s (Measure SCI & SCE about 5s)
RepeatabilitySpectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument ErrorΦ25.4mm/SCI, Within ΔE*ab 0.15
(Average for 12 BCRA Series II color tiles)
DimensionL*W*H=370x300x200mm
WeightApprox. 9.6kg
PowerAC 24V, 3A Power adapter power supply
Illuminant Life Span5 years, more than 3 million times measurements
Display7-inch TFT color LCD, Capacitive Touch Screen
Data PortUSB & Print serial port
Data StorageStandard 2000 Pcs, Sample 20000 Pcs
LanguageSimplified Chinese, Traditional Chinese, English,
Operating Environment0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment-20~50℃, 0~85%RH (no condensing)
Standard AccessoryPower Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component,
Optional AccessoryMicro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components, culture dish
NotesThe specifications are subject to change without notice.

 


Our Valued Clients

FAQs About YS6010 Benchtop Spectrophotometers

Our machine is packed by standard export wooden box, it won’t be damaged. We’ve delivered many testing machines abroad by sea or by air without damage.

When detecting color differences, the first factors to consider when selecting a light source include its stability, directionality, lifespan, and the effectiveness of the ultimately obtained spectral curve. The illuminant of a colorimeter is a fixed bulb, such as a tungsten lamp,LED light or a long-life xenon lamp. However, for the same color sample, the results displayed by the instrument vary under different light sources. This is because different light sources cause different absorption and reflection of light on the sample, leading to differences in how both the human eye and the instrument perceive the color. 

In general, the D65 light source is used in the application of coil steel inks for construction. The D65 light source is equivalent to average daylight. Most coil steel inks for construction are used outdoors, and sunlight is regarded as the standard light source in outdoor environments. For household appliance coil steel inks, due to their usage characteristics, they are mostly used indoors. Therefore, the A standard light source is adopted for color measurement of samples based on indoor lighting conditions. The A light source is a carefully specified tungsten light source. Other light sources, such as fluorescent light sources, can be used in many types of applications. For example, some textile factories use fluorescent light sources. Therefore, a reasonable light source should be selected as the mutually recognized measurement method based on actual usage conditions and user requirements. Once agreed upon by both parties, color measurement must be conducted under the same conditions. This helps reduce unnecessary systematic errors and human errors, achieving the optimal consistency in color measurement. 

The 3nh high-precision spectrophotometric colorimeter adopts a combined LED light source with long lifespan and low power consumption, which includes UV (ultraviolet) and UV-excluded options. This design can meet the color difference detection needs of different users and supports the selection of multiple light source modes.

Yes, we can offer Spectrodensitometer quality certification issued by our lab free of charge, or issued by third-party international inspection Organizations with extra charge, please contact us for confirmation.

Who are we? Threenh Technology: 22-Year Professional Color Measurement Solution Provider

Threenh Technology is a Chinese professional Measurement Instrument manufacturer with 22 years of industry experience, specializing in the field of color measurement and surface gloss detection. Integrating research and development, design, production, marketing, and sales, the company takes technological innovation as its core and is committed to providing global customers with high-precision and intelligent testing instruments as well as professional solutions.


A spectrophotometer and colorimeter are certain instruments used by scientists to measure color by quantifying reflected or transmitted light. The results are presented in color spaces, such as L*a*b*, RGB, or XYZ. This enables the accuracy of comparison and tracking of the changes in color in chemical or material research.

Related Benchtop Spectrophotometers You May Also Like

Give us a call!

Discuss your project with one of our product specialists:

0086 755 26508999

Need pricing?

We respond to quote requests within 1 business day.

service@3nh.com

Already know what you need?

Submit a demo request for the product you're interested in.

Get a Demo
Leave Your Message
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it. Privacy policy