Helps Enterprises Improve Product Quality
With its excellent measurement accuracy and stability, YS6010 assists enterprises in strictly controlling the color quality of products, enhancing product competitiveness, and winning market favor.7-inch TFT true color capacitive touchscreen, full light source, illumination mode: reflection D/8° and transmission D/0° (including/excluding UV measurement). It features stable color measurement and large storage capacity.
Key Highlights
256 Double Array CMOS Image Sensor
φ25.4mm/15mm/8mm/4mm 4 measuring apertures
7 inches TFT Color Capacitive Touch-screen
Built-in camera locating
PreciseLab data, used for color matching and accurate color transmission
Data storage 20000 pieces test result
Powerful extended functions at the PC software
The 3nh YS6010 benchtop spectrophotometer is an instrument designed to measure the color and spectral properties of objects or substances. It operates by measuring and analyzing data on the wavelengths of light absorbed, transmitted, or reflected by the sample under test. This information can be applied in various fields, including color matching, quality control, material analysis, and scientific research.
YS6010 is a benchtop grating spectrophotometer instrument which is developed by 3nh independently with independent intellectual property. YS6010 has many features, like 7 inches TFT capacitive touch screen display, full illuminants, reflective d/8 and transmissive d/0 geometry(including or excluding UV). With very stable and precise color measurement, large storage and powerful PC software all makes YS6010 ideal for color analysis within R&D and laboratory environments.

Features
1, High configuration of hardware: 7 inches TFT Color Capacitive Touch-screen Display; Concave Grating.
2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED.
3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.
4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.
5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.
6, Wavelength range 360nm – 780nm. Built-in 400nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.
7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.
8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.
9. A variety of optional accessories: Reflection sample holding tool, transmission fixture, micro 4mm aperture transmission test components, instrument inversion test components, applicable to more working conditions;
10, Big capacity data storage, for 20000 pieces test result.
11, Built-in camera locating.
12, More powerful extended functions at the PC software.
Application Industry
YS6010 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.

With its excellent measurement accuracy and stability, YS6010 assists enterprises in strictly controlling product color quality, enhancing product competitiveness, and winning market favor.
YS6010 Technical Specification
| Model | YS6010 Benchtop Spectrophotometer |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 5nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), APHA/Hazen/Pt-Co, Saybolt MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness,Gardner Index, 555 Index, Haze(ASTM D1003) |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75, F1,F2,F3,F4,F5,F6, F7,F8,F9,F10,F11,F12, CWF,DLF,TL83,TL84,TPL5,U30 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
| (Average for 12 BCRA Series II color tiles) | |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 9.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Print serial port |
| Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components, culture dish |
| Notes | The specifications are subject to change without notice. |
FAQs About YS6010 Benchtop Spectrophotometers
For wallpaper color consistency & quality control (including solid-color, printed, textured, and embossed wallpapers), these 3nh spectrophotometers deliver optimal performance:
d/8° integrating sphere, SCI/SCE dual mode
ΔE*ab ≤ 0.01 (repeatability), IIA ≤ 0.1
Multi-apertures (Φ3/8/15/25mm) — ideal for large patterned wallpapers
UV control (for optical brighteners in paper)
Best for: Lab formulation, color standardization, batch-to-batch consistency

d/8° (SCI/SCE), ΔE*ab ≤ 0.02
Handheld, fast, non-destructive
Large aperture (Φ20mm) averages out texture/pattern unevenness
Best for: Production line checks, warehouse incoming inspection, on-site matching

d/8°, interchangeable apertures (Φ4/8mm + 1×3mm)
High stability for rough/embossed surfaces
UV included for fluorescent inks/papers
Best for: Complex printed, textured, or metallic-effect wallpapers

45/0 geometry, ΔE*ab ≤ 0.04
Touchscreen, easy operation
Best for: Uniform solid-color wallpapers, basic production QC

Top lab precision: TS8560
Best portable production: TS7700
Best for textured/patterned: PS2080
Economical routine QC: NS800
At most of time, we have Spectrophotometer stock in the factory. Generally it is 1-3 working days after the payment confirmed. After shipped, we will email you the tracking number. You can check the shipping status of your order on the website. If you are in urgent need, we can consider making special arrangement for you.
The color of chemical products is measured by using a colorimeter or spectrophotometer. The instruments measure the amount of light that gets absorbed or reflected by a substance. It may be used to determine concentration, purity, or compliance with product standards.
Many people might answer "with the human eye", but this is actually not comprehensive. The human eye cannot accurately distinguish the colors of similar objects. Furthermore, everyone's perception of color varies. Therefore, people have developed color measurement tools based on the CIE color system.
Currently, there are two main types of commonly used colorimeters, as follows:
Colorimeter - It is an ideal choice for quality control (QC) on production lines, used to detect color differences.
Spectrophotometer - It is suitable for the development of color characteristics and color analysis in laboratories.
For premier glass quality grading (color, transmittance, haze, coating uniformity, architectural/auto/optical glass), the top 3nh & industry-leading instruments are:
d/8° integrating sphere, 360–780nm, UV adjustable
Dual mode: reflectance + transmission
ΔE*ab ≤ 0.015, IIA ≤ 0.2, haze measurement
Multi-apertures (Φ4/8/15/25.4mm)
Ideal: colored glass, coated glass, optical glass, lab R&D
d/8° sphere, SCI/SCE, UV control
ΔE*ab ≤ 0.01 (repeatability)
Large transmission compartment
Best for: high-end architectural glass, Low-E coated glass
d/8° (SCI/SCE), ΔE*ab ≤ 0.02
Handheld, fast, non-destructive
Best for: line checks, incoming glass, on-site grading
45/0 geometry, ΔE*ab ≤ 0.04
Touchscreen, rugged
Best for: solid-color glass, routine QC
Top lab: YS6060
Ultra-precision: TS8560
Portable production: ST70
Economical QC: NS810
Discuss your project with one of our product specialists:
0086 755 26508999We respond to quote requests within 1 business day.
service@3nh.comSubmit a demo request for the product you're interested in.
Get a Demo