| Model | YS6010 Desktop Color Spectrophotometer |
|---|---|
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ; SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source; Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture |
Reflectance: Φ30 mm/Φ25.4 mm; Φ10 mm/Φ8 mm; Φ6 mm/Φ4 mm Transmittance: Φ30 mm/Φ25.4 mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN |
| Color Difference Formula |
ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,Δ E (Hunter) ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter) |
| Other Colorimetric Index | WI(ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI(ASTM D1925, ASTM 313),TI(ASTM E313, CIE/ISO), | |
| Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, Cobalt platinum index, Gardner, 8° Glossiness,555 tone classification | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability |
Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
| Inter-instrument Error |
Φ25.4mm/SCI, Within ΔE*ab 0.15 (Average for 12 BCRA Series II color tiles) |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 16kg |
| Measurement Mode | Single Measurement, Average Measurement |
| Locating Method | Camera View Finder Locating |
| Power | AC 24V, 2A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB |
| Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
| Language | English, Chinese |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, White and Black Calibration Cavity, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber. |
| Optional Accessory | Micro Printer, Transmission test fixture component, Inspector Green Board |
|
Notes: The specifications are subject to change without notice. | |
Haze refers to the example and optical quality of transparent materials such as plastics, glasses, and films. Haze describes the amount of light that ....
At ThreeNH, that integrates colorimeters as the scientific and capture truth and vision. It human sight science, embraced measurement, and vision, enabling industries to standardize, reproduce, precise, and perfect colors.
Color accuracy is crucial in this process. This is made possible by the 3nh CR8 spectrocolorimeter. The slag can be transformed to value-added pigment products with the CR8’s reliable data in color measurements and differences.
Spectrophotometers offer detailed spectral analysis while colourimeters provide quick reliable checks. Other instruments like densitometers and gloss meters address specialised needs. Knowing their uses helps businesses maintain quality reduce waste
What is an Inline Spectrophotometer or colorimter? They monitor color in real time and enable snap adjustments to prevent corrective actions that may prove large scale and below acceptable color quality for any production batch.
Within 3NH, the most discussed are NH310 and NR110. On the surface, they come off as the same device: color measurement technology meant to be used outside of the lab, portable, etc.
color consistency affects the quality of the products as well as brand perception. A metal colorimeter is an instrument that guarantees objective and precise color measurement of various metal surfaces. So, you can avoid any subjective conclusions.
Two of the most common are D65 and TL84. It‘s important to understand how they are different if you do colour-critical work. This article will give a detailed comparison between D65 and TL84
Introduction And in a world where color accuracy is critical to numerous industries, there is an increased need for both an industry standard and an e....
Discuss your project with one of our product specialists:
0086 755 26508999We respond to quote requests within 1 business day.
service@3nh.comSubmit a demo request for the product you're interested in.
Get a Demo